12" W x 8" H CLEAN MACHINE SS Belt Washer, Elect Heated Wash, Rinse & Blow-Off AGE: 2008 MODEL NUMBER: CM12 SPECIFICATIONS: All Stainless Steel Construction Belt Width: 12" Opening Height: 6-1/2", Modifiable to 10" Floor to Top of Belt: 43" 16" Load Length 36" Long Wash Section: (5) Top Spray Bars with 3/2/3/2/2 Nozzles (3) Bottom Spray Bars with 3 Nozzles Each (3) 12 kW Indeeco Electric Heaters, 480/3 3 HP Pump with Variable Frequency Drive, AB Powerflex Gusher Pump Auto Fill Float with Overfill Safety Float Dual Removable Chip Screen Sloped Tank Bottom with Wash-Out Nozzles 24" Long Quiet Zone 36" Long Rinse Section: (3) Top and Bottom Spray Bars, 3 Nozzles Each (2) Chromalox 9 kW Electric Heaters 480/3 3 HP Pump with Variable Frequency Drive, AB Powerflex Gusher Pump Auto Fill Float with Overfill Safety Float Dual Removable Chip Screen Sloped Tank Bottom with Wash-Out Nozzles 48" Blow-Off Section: Regenerative Type Air Knife Air Tube with Drilled Holes 5 HP with (2) 24" x 24" x 1" Filters 16" Unload Length EQUIPPED WITH: Push Button Start and E-Stop Honeywell Temperature Control on Both Tanks with Hi/Low Alarms 1/2 HP Power Flex Variable Drive AB Micro Logic 1500 PLC Control Quick Panel JR TCP Operator Interface Stainless Steel Conveyor Belt Wired for Exhaust Fan System (Did Not Ship with Washer) Wired for Belt Type Oil Removal in Wash Tank (Missing) Both Overflow and Bottom Drains CURRENT REPLACEMENT COST PER MANUFACTURER IS $130,000 CONDITION: Excellent
Specifications
| Belt Width (mm) | 304.8 |
|---|---|
| Blow Off Section Filter Count | 2 |
| Blow Off Section Filter Size (mm) | 609.6 |
| Blow Off Section Length (mm) | 1,219.2 |
| Blow Off Section Motor (hp) | 5 |
| Condition | excellent |
| Construction Material | stainless_steel |
| Floor To Top Of Belt (mm) | 1,091.2 |
| Load Length (mm) | 406.4 |
| Opening Height (mm) | 165.1 |
| Opening Height Modifiable To (mm) | 254 |
| Operator Interface | Quick Panel JR TCP |
| Plc Control | AB Micro Logic 1500 |
| Power Flex Variable Drive (hp) | 0.5 |
| Quiet Zone Length (mm) | 609.6 |
| Rinse Section Electric Heaters (kW) | 18 |
| Rinse Section Heater Voltage | 480/3 |
| Rinse Section Length (mm) | 914.4 |
| Rinse Section Pump (hp) | 3 |
| Rinse Section Pump Type | AB Powerflex Gusher |
| Rinse Section Spray Bars | 3 |
| Unload Length (mm) | 406.4 |
| Wash Section Bottom Spray Bars | 3 |
| Wash Section Electric Heaters (kW) | 36 |
| Wash Section Heater Voltage | 480/3 |
| Wash Section Length (mm) | 914.4 |
| Wash Section Pump (hp) | 3 |
| Wash Section Pump Type | AB Powerflex Gusher |
| Wash Section Top Spray Bars | 5 |
Request a quote from Bass Machinery
Tell Bass Machinery what you need. They'll reply directly to you.
More in Process Plant
36" W x 2-1/2" H JENFAB Belt Washer, Wash/2x Rinse/Phos/Rinse/Seal/Hot B/O, Gas
JENFAB · 3602 · 2012
Bass Machinery
15.5" W x 18" H MIDBROOK Belt Washer, Hot Wash/Regen Blow-Off, Rebuilt 2005
Midbrook · MD-12-E-1080-MC-EF · 2005
Bass Machinery
24" W x 12" H MIDBROOK 3-Stage Belt Washer, Elect Heated Wash/Rinse, Regen B/O
Midbrook · 5024W/R/BO · 2001
Bass Machinery
9 KW, PELTON HYDRO TURBINE W/ 110 VDC GENERATOR, 1000/650 RPM; -1
Utilities Service Inc / Ideal Electric & Manufacturing Co · Pelton / DI D120-18
Belyea Company, Inc.
6000/6500 KW, Inlet 290/377 PSIG @ 707/752 DEG. F, 6600 V/3/50 HZ. SIEMENS
Siemens
Belyea Company, Inc.
615045 KW, INLET 3515 PSIG AT 1050 DEG. F* GE, GE, 2009 UNUSED SUPER CRITICAL-1
General Electric · 2009
Belyea Company, Inc.