615045 KW, INLET 3515 PSIG AT 1050 DEG. F* GE, GE, 2009 UNUSED SUPER CRITICAL-1 (GENERATOR AND STEAM GENERATOR MAY BE BOUGHT SEPARATELY) STEAM GENERATOR Manufacturer .......... Alstom Type................... Once through, Supercritical w/ reheater MCR.....................4,629,000 #/hr, 3790 PSI at 1050/1105 Deg. F Fuel....................Bituminous coal only or a combination of bituminous coal and petcoke (up to a 70%/30% blend) STEAM TURBINE Manufacturer........... General Electric Rating................. 615045 KW Stages................. 22 Stages HP Inlet.............. 3515 PSI @ 1050 Degr. F Exhaust Pressure....... 3.45" HgA GENERATOR Manufacturer........... General Electric Rating................. 750000 KVA Cycles................. 60 HZ Power Factor........... 0.9 P.F. ADDITIONAL SCOPE OF SUPPLY: Plant design heat rate with this power block is approximately 8725 BTU/kw-hr with turbine control valves wide open (VWO) Design documentation of the power block (drawings, specifications, calculations, 3D modeling) Turbine Generator Auxiliary Skids Steam Generator Engineering and Supply Steam Surface Condenser Materials Only -Stainless Steel tube blank plates and wide band coils for tubing fabrication (in storage) Feedwater Heater Materials Only - Stainless Steel tube strip coils and carbon steel ingots for forgings (in storage) Condensate Pumps Boiler Feed Pumps BFP Booster Pumps Startup Boiler Feed Pump (Electric 25%) Critical Piping High Pressure Valves #1 High Pressure Valves #2 Severe Service Control Valves More details can be provided after receiving project and funding details.
Specifications
| Condition | unused |
|---|---|
| Design Heat Rate Btu Per Kwh | 8,725 |
| Exhaust Pressure Inga | 3.45 |
| Fuel Type | bituminous_coal_or_petcoke_blend |
| Generator Cycles (Hz) | 60 |
| Generator Power Factor | 0.9 |
| Generator Rating (kVA) | 750,000 |
| Hp Inlet Pressure (psi) | 3,515 |
| Hp Inlet Temperature Degf | 1,050 |
| Steam Generator Manufacturer | Alstom |
| Steam Generator Mcr Lbhr | 4,629,000 |
| Steam Generator Pressure (psi) | 3,790 |
| Steam Generator Reheat Temperature Degf | 1,105 |
| Steam Generator Temperature Degf | 1,050 |
| Steam Generator Type | once_through_supercritical_with_reheater |
| Steam Turbine Rating (kW) | 615,045 |
| Steam Turbine Stages | 22 |
Request a quote from Belyea Company, Inc.
Tell Belyea Company, Inc. what you need. They'll reply directly to you.
More in Process Plant
6000/6500 KW, Inlet 290/377 PSIG @ 707/752 DEG. F, 6600 V/3/50 HZ. SIEMENS
Siemens
Belyea Company, Inc.
9 KW, PELTON HYDRO TURBINE W/ 110 VDC GENERATOR, 1000/650 RPM; -1
Utilities Service Inc / Ideal Electric & Manufacturing Co · Pelton / DI D120-18
Belyea Company, Inc.
1600 KW, 234 FT Hd., 2300 V/3/60 HZ, 1983, HYDRO WEST, 900 RPM:-1
Hydro West / Ideal · V21320-17 · 1983
Belyea Company, Inc.
101994 KW, Inlet 1250 PSIG/950 DEG F EXH: 3"HGA, 13800 V/3/60 HZ:-1
General Electric · 1975
Belyea Company, Inc.
10000 HP, Press/In 580 PSIG, 5370 RPM, GE, 1957 - 1
General Electric · 1957
Belyea Company, Inc.
1000 PSI, CHIP BLASTER J4-1000, 2003,
Chip Blaster · J4-1000 · 2003
Standard Industrial Machinery