Kemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34"Wx35"H part,self contained htd tanks,90s   Our stock number: 16185

Kemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90s

Click on picture below for larger version
Kemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90sKemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90sKemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90sKemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90s
Kemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90sKemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90sKemac, 3-Stg,Slat Blt Pass Thru,Hi-Veloc Blow-Off,34 Wx35 H part,self contained htd tanks,90s

Model/Type: 2-Stage w/Blow-Off -
New: 1990's

SPECIFICATIONS AND DESCRIPTION:
Overall dimensions: 589"L x 91"W x 87"H
Note: Overall Height to top of Blow Off Fan: 10' above floor
Tunnel Dimensions: approximately 34"W x 35"H
Conveyor Data: Slat Belt- slats on 6" centers 34" Wide
Vari-Speed Drive - Helical bevel integral gearmotor - torque rated @
7260 Lb-In / 6.5 RPM - 1 HP
Reversing capability - Galvanized steel construction, supported by
rollers
Entrance load area: 10' / Exit unload area: 15'L /
Elevation height above floor - approx 40"
Conveyor speed: Variable 0 - 10 fpm
Construction: 7 Gauge Welded carbon steel, tanks and upper housing
2" insulation (mineral wool and 16 ga carbon skin
Gross weight: approx 12,000#
Work capacity: 34"W x 35"H - Max work load weight: 2500#

Design Stages of Operation:
-Stage 1: Heated Wash - 1000 gallon tank) -
40 HP / 320GPM Gusher type vertical pump rated @ 130 PSI
7 spray risers
-Stage 2: Heated Rinse - 400 gallon tank) -
20 HP / 250 GPM Gusher type vertical pump rated @ 60 PSI
4 spray risers
Heat for tanks is supplied by plant steam system - a hot water boiler
could be added off-line to produce
Heated hot water if steam heat unavailable in purchaser's plant -
tanks equipped with steam coils
Spray nozzles are located on all sides of the work - construction:
#304 SST
Tank drains with tanks pitched to a 2" drain nipple with ball valve,
equipped with solution filters
Tanks protected with 2" emergency overflow dam in wash tank
A 300 gallon solids separator tank(solution tank) is includedri-
heated, equipped with steam coils

Blow-Off Section: Ambient Air 'Blow-Off' Section - 15 HP blower fan
rated @ 2800 SCFM @ 18" Dia WC
Recirculated air, high pressure - low volume design - equipped with 2
sets of air knives

Designed use: Automotive Engine Blocks

ELECTRICS: 220/440 volt 3 phase 60 hz

CONDITION: Unit is in very good condition - removed from service, in
storage
ready for immediate release and delivery -.