JR GREEN IN-LINE PAINT LINE WET OR DRY POWDER QUOTE# 75C-682
MODEL/TYPE: Custom designed 48W x 90H x 12-16L Parts AGE: New 2000
The line consists of a power & free overhead monorail conveyor system, work load-bars, pre-treatment
washer, dry-off oven and an in-line Cure oven chamber.
NOTE: They system originally contained a large environmental room with (3) in-line automatic powder
ooths none of this equipment is available or included in this line.
DESCRIPTION OF LINE COMPONENTS:
Basic Line Capacity:
Designed Load Bar cap/work envelope: 48W x 90H x 21L w/48 Conv. Drop
Work openings thru the washer & ovens:48 W x 90H
Designed work L thru turn radius- in the ovens:21 L (approx)
Designed load factor1000#
Power & Free Monorail system OEM: Unibilt Conveyor systems Approx 1300 OAL
Supported from ceiling clear clearance at floor level / no support stantions
Designed speed variable from 10 16 FPM(1) drives 2 HP each
4 HD Chain - Hangers located on 24 centers
Equipped with an auto lube device and chain cleaner
Washer - Pre-treatment System: 6-stage, in line all SST construction (304 type) a
prox 180 OAL
Washer tunnel: 90 W x 120H above tanks, Drain-backs throughout, dwell times be
ow based on 15 FPM:
Stage #1: Heated Alk pre-wash (140F) 4000 gal, 60 seconds, 330 nozzles
Stage #2: Heated Alk Wash (140F) 6000 gal, 90 seconds, 506 nozzles
Stage #3: Ambient Rinse, 2000 gal, 40 seconds, 220 nozzles
Stage #4: Heated Iron Phos soak, (120F), 4000 gal, 120 seconds, 330 nozzles
Stage #5: Ambient Rinse, 2000 gal, 40 seconds, 220 nozzles
Stage #6: Final Ambient Rinse, 2000 Gal, 40 seconds, 220 nozzles
All PVC and adjustable poly nozzles and risers used throughout, vertical gusher pumps, tank skimmers
& drains
Dry-off Oven: L configuration: 50L 72L Gas fired, convection
; recirculated Hot air
Designed operating temperature: 300F / typical operating temp for water drying: 150F
Construction: 6 thick aluminized interlocking steel panel construction double wall
design
Tunnel dimensions: 76 W x 156H
(1) Maxon OvenPak gas burner rated @ 2.5 M BTU
Honeywell UDC 2000 series controls
5 HP Recirculation blower system rated @ 35000 CFM and exhaust blower rated @ 5000 CFM
RETURN
to complete inventory display
RETURN
to our home page