4" W. x 5" H. x 96" L., Abbott, No. 3ZSCR-04-96HH3, Temperature: 2150 F, 3-Zone, Hydrogen/Nitrogen Atmosphere Muffle, A-B Electronics, SST Belt, 2-12 IPM, Ne   Our stock number: 27386

4 W. x 5 H. x 96 L., Abbott, No. 3ZSCR-04-96HH3, Temperature: 2150 F, 3-Zone, Hydrogen/Nitrogen Atmosphere Muffle, A-B Electronics, SST Belt, 2-12 IPM, Ne

4” ABBOTT BELT TYPE BRAZING FURNACEQUOTE# 27-386

MODEL/TYPE: 3ZSCR-04-96HH3-2150 Brazing Furnace w/Muffle NEW: 2005

SPECIFICATIONS & DESCRIPTION:
Overall Dimensions: 29’ OAL x 54"W x 79” H
Equipped with two tables: 60” Long for loading / 24" Long for unloading, both 27” wide

Pass Thru Type Furnace with Nitrogen & Hydrogen Atmosphere Muffle system

Designed work capacity: 2-1/4” Dia x 2-1/2” H Designed part
t: 175 grams each
Production rating: 120 – 160 pieces /Hr ( 30 pcs/Hr min) Belt speed: 5 –
7 ipm
Note: The work design dimensions and production rates can vary depending on the actual product.

Heat Zone info:
Pretreat zone up to 300 C /- 5 C per minute - Actual time: 5 minutes min.
Max temp Rampdown – 150 C adjustable @ 2.5%
Muffle: 30 Square inches – entrance opening: 5-1/2” x 5-1/2” equipped w/adjust door
to conserve Atmosphere
Shape: Square, Material: Silicon Carbide, OAL: 112”, ID: 5.5” x 5.5
8;, (2) 65’ sections
Braze Time @ temperature: 2 minutes min. 4” (3) Zone, Electric
Chamber dimensions: Hi Heat: 96” @ 2150 F - Heat Chambers constructed of ¼” Hot
olled steel
Temperature Controls: Honeywell Model 3300 (1)/Zone & Model 2300 Over-Temp control
Insulation: Ceramic Fiber rated @ 2300F - Atmosphere: 100%Hydrogen/Nitrogen
Furnace electronics – logic: Allen-Bradley Micrologix system

Cooling zone info:
Conventional water-jacketed coolers - equipped with two cooling chambers & three Curtin boxes
Cooling Transition: 8” - Cooling Chambers #1 & #2: 36” ea
Curtin Box #1: 18” - Cooling Chamber #3: 36” - Curtin Box #2: 30” - Trans
tion 3” - exit to U/L
Water Jacketed cooling system comprised of hot rolled steel inner & outer liners
Equipped with automatic water flow monitoring system – water requirements: approx 300 gallons/
r
Dew-point info: continuously maintained @ -55 C (typical temp range, continuous: 65C to -70C)


Conveyor Belt Data:
Approx 70’ OAL x 4” wide , Construction: SST, Speed: 2 – 12 ipm, Speed Control
EM: Red Lion
DC motor drive w/double reduction gear box & drive train - equipped with deviation warning syste