TURBINE:
Manufacturer:................Toshiba
Power Rating:................215000 KW
Inlet:.......................104 bar (1508 psig)
Steam Flow:..................270 kg/s Max; 45 kg/s Min
Type:........................Condensing
Configuration:...............Single Casing Single Flow Impulse
Last Stage Bucket Length:....42" (Nominal)
Extractions: MP2: 22 bar, MPI: 10 bar, LP: 4.5 bar, Feed Water: 0.4 bar
Rotation:....................CCW (viewed from front of Turbine)
Speed:.......................3,000 rpm
Allowable Cycle Change:......48.5 - 50.5 Hz
GENERATOR:
Manufacturer:................Toshiba
Rating:......................250 MVA
Output Voltage:..............18 kV
Output Current:..............8019 A
Frequency:...................3 Ph, 50 HZ
Speed:.......................3000 RPM
Cooling:.....................Air to Water Cooled
The generator consists of the stator, rotor, cover, bearing and air-to-water
cooler. The stationary armature is attached to and supported by generator
base. The rotor is supported by the bearings. Air-to-water coolers are mounted
above the stator. The cooling system is completely enclosed to prevent
exposure to dust and moisture.
HISTORY:
Delivered 2009, currently stored indoors and secured, Turbine & Generator
completely sealed. Silica gel is inserted in the Turbine & Generator and
regularly replaced. Equipped with electronic monitoring sensors for humidity &
temperature with criteria from Toshiba for storage, monitoring report
generated monthly, inspection of unit every (2) weeks, thorough inspections
were done every (6) months until 2012, then yearly, inspection protocols.