0C2187 CIRCUIT BREAKERS, AIR & VACUUM, CUBICLES(1000 V. TO 5000 V.)
EATON, 4160 V., SWITCHGEAR LINE-UP CONSISTING OF 4 COLUMNS WITH 6 BREAKERS Ref: 44400

EATON, 4160 V., SWITCHGEAR LINE-UP CONSISTING OF 4 COLUMNS WITH 6 BREAKERS
  
  

CB-19384 THRU CB-19389

One (1) Eaton Switchgear Line-up consisting of 4 columns with 6 breakers -
(1) 3000A, (2) 2000A, (3) 1200A with (1) 15 kva CPT drawer and (1) VT drawer
CONSISTING OF:

CB-19384
ONE (1) 3000A EATON 4.76V CIRCUIT BREAKER
Style 4A35142G47
60KV PEAK Impulse Voltage
60 Hertz
63 KA Rated Short-Circuit Current
V Range Fac-K 1.0
5 Cycle Interrupt
C&L Current 170KA PEAK
Motor - 125 VDC/AC
Close Current 6.6A - 104-127 VAC
CAP Trip 120 VAC BUS

Instruction Booklet: 32-255-1G
Wiring Diagram: 691C386H54
Weight: 525 LBS.


CB-19385
ONE (1) 2000A EATON 4.76V CIRCUIT BREAKER
Style 4A35142G46
60KV BIL
60 Hertz
63 KA Rated Short-Circuit Current
V Range Fac-K 1.0
5 Cycle Interrupt
C&L Current 170KA PEAK
Motor - 125 VDC/AC
Close Current 6.6A - 104-127 VAC
CAP Trip 120 VAC BUS

Instruction Booklet: 32-255-1G
Wiring Diagram: 691C386H54
Weight: 525 LBS.

CB-19385B - 15KVA CPT DRAWER


CB-19385C - VT DRAWER

CB-19386 & CB-19387
ONE (1) 1200A EATON 4.76V CIRCUIT BREAKER
Style 4A35142G45
60KV PEAK Impulse Voltage
60 Hertz
63 KA Rated Short-Circuit Current
V Range Fac-K 1.0
5 Cycle Interrupt
C&L Current 170KA PEAK
Motor - 125 VDC/AC
Close Current 6.6A - 104-127 VAC
CAP Trip 120 VAC BUS
Instruction Booklet: 32-255-1G
Wiring Diagram: 691C386H54
Weight: 525 LBS.

CB-19388
ONE (1) 1200A EATON 4.76V CIRCUIT BREAKER
Style 4A35142G45
60KV PEAK Impulse Voltage
60 Hertz
63 KA Rated Short-Circuit Current
V Range Fac-K 1.0
5 Cycle Interrupt
C&L Current 170KA PEAK
Motor - 125 VDC/AC
Close Current 6.6A - 104-127 VAC
CAP Trip 120 VAC BUS

Instruction Booklet: 32-255-1G
Wiring Diagram: 691C386H54
Weight: 525 LBS.


CB-19389
ONE (1) 2000A EATON 4.76V CIRCUIT BREAKER
Style 4A35142G46
60KV PEAK Impulse Voltage
60 Hertz
63 KA Rated Short-Circuit Current
V Range Fac-K 1.0
5 Cycle Interrupt
C&L Current 170KA PEAK
Motor - 125 VDC/AC
Close Current 6.6A - 104-127 VAC
CAP Trip 120 VAC BUS

Instruction Booklet: 32-255-1G
Wiring Diagram: 691C386H54
Weight: 525 LBS.













Belyea Co Inc
2200 Northwood Ave Easton PA 18045-2239
Tel: 610-515-8775 Fax: 610-258-1230
Email (Request Quote): info@belyeapower.com