Used Equipment
Used Equipment Used Equipment Network
Sign On  (Which am I?)
 User Email:    
Dealer Dlr#:      PW:  
Used Equipment
Used Equipment
Used Equipment
Buying Equipment
 >Recent Listings
 >Browse Listings
 >Enter Wanted
 >Periodic Bulletins
Selling Equipment
 >See Wanteds
 >Enter For-Sale
Dealers & Services
 >Search Dealers
 >Dealers by Specialty
 >Services & Supplies
 >Recent Brochures
How to Use UEN
 >Buying Equipment
 >Selling Equipment
 >Specialties & Categories
How to Advertise
 >Equipment Dealers
 >Services & Supplies

Used Equipment Directory

feedburner   Subscribe to RSS

Used Equipment
Home   >   Belyea Co Inc   >   --unknown-- 00 1900


0G2906 GENERATORS, A.C., STEAM TURBINE DR., CONDENS'G
615045 KW, INLET 3515 PSIG AT 1050 DEG. F* GE, GE, 2009 UNUSED SUPER CRITICAL-1 Ref: 37295

615045 KW, INLET 3515 PSIG AT 1050 DEG. F* GE, GE, 2009 UNUSED SUPER CRITICAL-1
  
     

(GENERATOR AND STEAM GENERATOR MAY BE BOUGHT SEPARATELY)


STEAM GENERATOR

Manufacturer .......... Alstom
Type................... Once through, Supercritical w/ reheater
MCR.....................4,629,000 #/hr, 3790 PSI at 1050/1105 Deg. F
Fuel....................Bituminous coal only or a combination of
bituminous coal and petcoke (up
to a 70%/30% blend)

STEAM TURBINE

Manufacturer........... General Electric
Rating................. 615045 KW
Stages................. 22 Stages
HP Inlet.............. 3515 PSI @ 1050 Degr. F
Exhaust Pressure....... 3.45" HgA

GENERATOR

Manufacturer........... General Electric
Rating................. 750000 KVA
Cycles................. 60 HZ
Power Factor........... 0.9 P.F.

ADDITIONAL SCOPE OF SUPPLY:

Plant design heat rate with this power block is approximately
8725 BTU/kw-hr with turbine control valves wide open (VWO)

Design documentation of the power block (drawings, specifications,
calculations, 3D modeling)
Turbine Generator Auxiliary Skids
Steam Generator Engineering and Supply
Steam Surface Condenser Materials Only -Stainless Steel tube blank
plates and wide band coils for tubing fabrication (in storage)
Feedwater Heater Materials Only - Stainless Steel tube strip coils
and carbon steel ingots for forgings (in storage)
Condensate Pumps
Boiler Feed Pumps
BFP Booster Pumps
Startup Boiler Feed Pump (Electric 25%)
Critical Piping
High Pressure Valves #1
High Pressure Valves #2
Severe Service Control Valves


More details can be provided after receiving project and funding
details.

Belyea Co Inc
2200 Northwood Ave Easton PA 18045-2239
Tel: 610-515-8775 Fax: 610-258-1230
Email (Request Quote): info@belyeapower.com
Web: www.belyeapower.com



- Search equipment by:  
 


Used Equipment
Used Equipment
Used Equipment
Used Equipment
UEN is a product of and is operated by Halliburton Systems Inc of Denville NJ
Used Equipment
Used Equipment