0G2906
GENERATORS, A.C., STEAM TURBINE DR., CONDENS'G
101994 KW, Inlet 1250 PSIG/950 DEG F EXH: 3"HGA, 13800 V/3/60 HZ:-1
Ref:
35863
|
|
|
STEAM TURBINE:
Manufacturer: General Electric
Rating: 101,994 kw
Type: Axial exhaust condensing, non
reheat
Inlet steam: 1250 psig/950 deg f
Exhaust steam: 3" Hga
Steam Flow: 763,000 lbs/hr @99,850 kw
Steam rate: 7.64 lbs/kwh
Extraction steam: only to deaerator and lp heater
Last stage blade: 20"
Speed: 3600 rpm
GENERATOR:
Manufacturer: General Electric
Rating: 115,000 kva @ 30 psig h2
Voltage: 13800 v, 3 phase, 60 hz
Type: Hydrogen cooled
Condenser: Two shells on sides
54,400 sq. ft
67,200 gpm
History:
Year Built: 1972 started up 1975
Last run: 1986
Part of combined cycle power plant.
SCOPE OF SUPPLY:<
Steam turbine (hp and Lp)<
Cross over pipe<
Generator <
Static Exciter with dc breaker<
Generator terminal box<
Bus duct<
Condenser<
Air ejector package<
Condensate Extraction pump with motor<
Circulating water pumps with motor<
Lube oil system<
Gland steam system<
Steam stop valve<
Steam pipe from valve to turbine inlet.<
Following items not included but, we can supply if needed<
Generator breaker <
Turbine and generator control panel<
Cooling Tower <
Belyea Co Inc
2200 Northwood Ave
Easton PA 18045-2239
Tel:
610-515-8775
Fax:
610-258-1230
Email (Request Quote):
info@belyeapower.com
Web:
www.belyeapower.com
|