EATON, 4160 V., SWITCHGEAR LINE-UP CONSISTING OF 4 COLUMNS WITH 6 BREAKERS
- Manufacturer
- Eaton
- Condition
- Used
Description
EATON, 4160 V., SWITCHGEAR LINE-UP CONSISTING OF 4 COLUMNS WITH 6 BREAKERS CB-19384 THRU CB-19389 One (1) Eaton Switchgear Line-up consisting of 4 columns with 6 breakers - (1) 3000A, (2) 2000A, (3) 1200A with (1) 15 kva CPT drawer and (1) VT drawer CONSISTING OF: CB-19384 ONE (1) 3000A EATON 4.76V CIRCUIT BREAKER Style 4A35142G47 60KV PEAK Impulse Voltage 60 Hertz 63 KA Rated Short-Circuit Current V Range Fac-K 1.0 5 Cycle Interrupt C&L Current 170KA PEAK Motor - 125 VDC/AC Close Current 6.6A - 104-127 VAC CAP Trip 120 VAC BUS Instruction Booklet: 32-255-1G Wiring Diagram: 691C386H54 Weight: 525 LBS. CB-19385 ONE (1) 2000A EATON 4.76V CIRCUIT BREAKER Style 4A35142G46 60KV BIL 60 Hertz 63 KA Rated Short-Circuit Current V Range Fac-K 1.0 5 Cycle Interrupt C&L Current 170KA PEAK Motor - 125 VDC/AC Close Current 6.6A - 104-127 VAC CAP Trip 120 VAC BUS Instruction Booklet: 32-255-1G Wiring Diagram: 691C386H54 Weight: 525 LBS. CB-19385B - 15KVA CPT DRAWER CB-19385C - VT DRAWER CB-19386 & CB-19387 ONE (1) 1200A EATON 4.76V CIRCUIT BREAKER Style 4A35142G45 60KV PEAK Impulse Voltage 60 Hertz 63 KA Rated Short-Circuit Current V Range Fac-K 1.0 5 Cycle Interrupt C&L Current 170KA PEAK Motor - 125 VDC/AC Close Current 6.6A - 104-127 VAC CAP Trip 120 VAC BUS Instruction Booklet: 32-255-1G Wiring Diagram: 691C386H54 Weight: 525 LBS. CB-19388 ONE (1) 1200A EATON 4.76V CIRCUIT BREAKER Style 4A35142G45 60KV PEAK Impulse Voltage 60 Hertz 63 KA Rated Short-Circuit Current V Range Fac-K 1.0 5 Cycle Interrupt C&L Current 170KA PEAK Motor - 125 VDC/AC Close Current 6.6A - 104-127 VAC CAP Trip 120 VAC BUS Instruction Booklet: 32-255-1G Wiring Diagram: 691C386H54 Weight: 525 LBS. CB-19389 ONE (1) 2000A EATON 4.76V CIRCUIT BREAKER Style 4A35142G46 60KV PEAK Impulse Voltage 60 Hertz 63 KA Rated Short-Circuit Current V Range Fac-K 1.0 5 Cycle Interrupt C&L Current 170KA PEAK Motor - 125 VDC/AC Close Current 6.6A - 104-127 VAC CAP Trip 120 VAC BUS Instruction Booklet: 32-255-1G Wiring Diagram: 691C386H54 Weight: 525 LBS.
Specifications
| Breaker Ratings | 3000A, 2000A, 2000A, 1200A, 1200A, 1200A |
|---|---|
| Close Current (a) | 6.6 |
| Close Voltage Vac | 115 |
| Frequency (Hz) | 60 |
| Interrupt Cycle | 5 |
| Motor Voltage Vdc Ac | 125 |
| Number Of Breakers | 6 |
| Number Of Columns | 4 |
| Peak Current Ka | 170 |
| Peak Impulse Voltage (kV) | 60 |
| Rated Short Circuit Current Ka | 63 |
| Trip Voltage Vac | 120 |
| Voltage (v) | 4,160 |
| Weight (kg) | 238.14 |
Request a quote from Belyea Company, Inc.
Tell Belyea Company, Inc. what you need. They'll reply directly to you.
More in Electrical
2000 Amp, ABB, No. 145 PMI 40-20, 145000 V., 1993, 40kA Short, HMB-1.5 Mech
ABB · 145 PMI 40-20 · 1993
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp, SQUARE D, FG2-15050-12, 15 KV, FLUARC, 240 VAC CHARGE/CLOSE, 48 VDC T
Square D · FG2-15050-12
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.