Used Equipment Network
v0 · pilot
1800 KVAR, SHALLBETTER, 13200/7620 V, 9 X 200 KVAR CANS, INDOOR, 3 PHASE, FUSED
Electrical·Capacitor Bank

1800 KVAR, SHALLBETTER, 13200/7620 V, 9 X 200 KVAR CANS, INDOOR, 3 PHASE, FUSED

Sold by Belyea Company, Inc.·Available·Last verified 3h ago
Manufacturer
Shallbetter
Year
1999
Condition
Used

Description

1800 KVAR, SHALLBETTER, 13200/7620 V, 9 X 200 KVAR CANS, INDOOR, 3 PHASE, FUSED B-13474: ONE (1) INDOOR HOUSED SHALLBETTER CAPACITOR BANK 13200/7620 VOLT 9 X 200 KVAR CANS DIVIDED INTO 2 STEPS - STEP 1 - 600 KVAR STEP 2 - 1200 KVAR FUSED 2 BUSHING 3 X REACTORS (ON EACH STAGE) 3 X SURGE ARRESTERS (ON EACH STAGE) 3 X OIL SWITCHES (ON EACH STAGE) KIRK KEY INTERLOCKS ON SECTIONS CONTAINING CAPACITORS AND DISCONNECT SWITCH STAGE 1: JOSLYN VERSAVAC 2 CAPACITOR BANK 600 KVAR 15 KV UNGROUNDED 25 KV SOLIDLY GROUNDED 200 AMP, 120 VAC LIST #3148X0302G1 WIRING DIAGRAM 3148B0819 95 KV BIL 3 X FUSED GE CAPACITORS, 7960, 200 KVAR, 2 BUSHING, SINGLE PHASE, 95 KV BIL, 60 HERTZ, MFG. 12/99, FUSING RATING 8.3 KV, 40 AMP, 50 KA 3 X SHALLBETTER REACTORS RATED 200 AMP, 20 MOCROHENRIES, CAT. #SB1-CLR-20-200 3 X ABB INTERMEDIATE CLASS SURGE ARRESTERS RATED 10 KV, 8.4 MCOV, STYLE #ER010AA008A 1 X ABB BAR TYPE CT RATED 13.8 KV, 25:5 RATIO, 11 KV BIL, 0.3 ACC, STYLE 7524A03G05 600 AMP ABB VERSA-RUPTER FUSED DISCONNECT SWITCH 13.8 KV CONTINUOUS, 17 KV MAX., 40 KA, CAT. #244-042-507 WITH 3 X GE EJO-1DD FUSES, 15.5 KV/125 AMP/60 HERTZ 1 X DOUBLE FUSED ABB PT RATED 13.2/13.2Y - 120, 60 HERTZ STAGE 2: RELAY & CONTROL SECTION 2 X CURRENT SENSING RELAYS, 2 X NEUTRAL CURRENT RELAYS 7 CONTROLS FOR ALL HEATERS 1 X GEC ALSTHOM (NOVAR 315 CONTROL) MODEL #N31561205CYBAAA JOSLYN VERSAVAC 2 CAP BANK RATED 1200 KVAR 15 KV (UNGROUNDED) 25 KV (SOLIDLY GROUNDED) 200 AMP 120 VAC CONTINUOUS LIST #3148X0302G1 WIRING DIAGRAM 3148B0819 95 KV BIL 6 X FUSED GE CAPACITORS, 7960 VOLT, 200 KVAR, 2 BUSHING, SINGLE PHASE, 95 KV BIL, 60 HERTZ, MFG. 1999, FUSE RATING 8.3 KV, 40 AMP, 50 KA 3 X SHALLBETTER REACTORS RATED 200 AMPS, 20 MOCROHENRIES, CAT. #SBI-CLR-20-200 3 X ABB INTERMEDIATE CLASS SURGE ARRESTERS RATED 10 KV, 8.4 MCOV, STYLE ER010AA008A 1 X ABB BAR TYPE CT RATED 13.8 KV, 25:5 RATIO, 11 KV BIL, 0.3 ACC STYLE 7524A03G05

Specifications

Can Capacity Kvar200
Frequency (Hz)60
Housingindoor
Number Of Bushings2
Number Of Cans9
Number Of Oil Switches3
Number Of Reactors3
Number Of Surge Arresters3
Phase3_phase
Stage 1 Amperage (a)200
Stage 1 Bil (kV)95
Stage 1 Capacity Kvar600
Stage 1 Control Voltage Vac120
Stage 1 Ct Bil (kV)11
Stage 1 Ct Ratio25:5
Stage 1 Disconnect Amperage (a)600
Stage 1 Disconnect Continuous (kV)13.8
Stage 1 Disconnect Ka40
Stage 1 Disconnect Max (kV)17
Stage 1 Fuse Rating (a)40
Stage 1 Fuse Rating Ka50
Stage 1 Fuse Rating (kV)8.3
Stage 1 Ge Capacitors Count3
Stage 1 Pt Voltage Primary13.2/13.2Y
Stage 1 Pt Voltage Secondary120
Stage 1 Reactor Microhenries20
Stage 1 Surge Arrester (kV)10
Stage 1 Surge Arrester Mcov8.4
Stage 1 Voltage Grounded (kV)25
Stage 1 Voltage Ungrounded (kV)15
Stage 2 Amperage (a)200
Stage 2 Bil (kV)95
Stage 2 Capacity Kvar1,200
Stage 2 Control Voltage Vac120
Stage 2 Ct Bil (kV)11
Stage 2 Ct Ratio25:5
Stage 2 Fuse Rating (a)40
Stage 2 Fuse Rating Ka50
Stage 2 Fuse Rating (kV)8.3
Stage 2 Ge Capacitors Count6
Stage 2 Reactor Microhenries20
Stage 2 Surge Arrester (kV)10
Stage 2 Surge Arrester Mcov8.4
Stage 2 Voltage Grounded (kV)25
Stage 2 Voltage Ungrounded (kV)15
Total Capacity Kvar1,800
Voltage Primary (v)13,200
Voltage Secondary (v)7,620

Request a quote from Belyea Company, Inc.