1600 Amp, ALSTOM, DT1-72.5 F1, 69 KV, 2002, 125 VDC CLOSE & TRIP, CRR4-5 MECH.
- Manufacturer
- ALSTOM
- Model
- DT1-72.5 F1
- Year
- 2002
- Condition
- Used
Description
1600 Amp, ALSTOM, DT1-72.5 F1, 69 KV, 2002, 125 VDC CLOSE & TRIP, CRR4-5 MECH. CB-18328: ONE (1) 1600 AMP ALSTOM SF6 CIRCUIT BREAKER TYPE DT1-72.5 F1 72.5 KV 40 KA SHORT CIRCUIT 350 KV BIL 3 CYCLE INTERRUPT RATED K FACTOR 1 60 HERTZ 98.6 PSIG OPERATING PRESSURE 48 LBS. OF GAS CRR4-5 SPRING CHARGED MECHANISM -30 DEG. C TO +40 DEG. C TEMPERATURE RANGE 125 VDC CLOSE & TRIP 120 VAC MOTOR WIRING DIAGRAM DT09CO724 INSTRUCTION MANUAL DT0P-IM 12 X 2000:5 MRCT'S C800 CAPACITANCE CURRENT SWITCHING INFO: RATED OVER VOLTAGE TRANSIENT FACTOR: 2.0 RATED OPEN-WIRE LINE CHARGING CURRENT: 100 A RATED ISOLATED SHUNT CAPACITOR BANK CURRENT: 630 A RATED BACK-TO-BACK SHUNT CAPACITOR BANK CURRENT: 630 A RATED TRANSIENT INRUSH CURRENT PEAK: 25 KA RATED TRANSIENT INRUSH CURRENT FREQUENCY: 3360 HZ RATED OUT OF PHASE SWITCHING CURRENT: 10 KA 5328 LBS. 1313"H X 103.9"W X 78"D
Specifications
| Amperage (a) | 1,600 |
|---|---|
| Bil (kV) | 350 |
| Close Trip Voltage Vdc | 125 |
| Depth (mm) | 1,981 |
| Frequency (Hz) | 60 |
| Gas Weight (kg) | 21.772 |
| Height (mm) | 33,350 |
| Interrupt Cycles | 3 |
| K Factor | 1 |
| Mechanism Type | CRR4-5 spring charged |
| Motor Voltage Vac | 120 |
| Operating Pressure (kPa) | 680.3 |
| Operating Temperature Max (c) | 40 |
| Operating Temperature Min (c) | -30 |
| Rated Back To Back Shunt Capacitor Bank Current (a) | 630 |
| Rated Isolated Shunt Capacitor Bank Current (a) | 630 |
| Rated Open Wire Line Charging Current (a) | 100 |
| Rated Out Of Phase Switching Current Ka | 10 |
| Rated Over Voltage Transient Factor | 2 |
| Rated Transient Inrush Current Frequency (Hz) | 3,360 |
| Rated Transient Inrush Current Peak Ka | 25 |
| Short Circuit Capacity Ka | 40 |
| Voltage (kV) | 72.5 |
| Weight (kg) | 2,419.5 |
| Width (mm) | 2,639 |
Request a quote from Belyea Company, Inc.
Tell Belyea Company, Inc. what you need. They'll reply directly to you.
More in Electrical
2000 Amp, ABB, No. 145 PMI 40-20, 145000 V., 1993, 40kA Short, HMB-1.5 Mech
ABB · 145 PMI 40-20 · 1993
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp, SQUARE D, FG2-15050-12, 15 KV, FLUARC, 240 VAC CHARGE/CLOSE, 48 VDC T
Square D · FG2-15050-12
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.
1200 Amp 145 kV Southern States Circuit Switcher, CSH-B
Southern States · CSH-B
Belyea Company, Inc.