1200 Amp, ALSTOM, VXC 8025/36-2.E1, 38 KV, 2001, VACUUM, OUTDOOR:1
- Manufacturer
- ALSTOM
- Model
- VXC 8025/36-2.E1
- Year
- 2001
- Condition
- Used
Description
1200 Amp, ALSTOM, VXC 8025/36-2.E1, 38 KV, 2001, VACUUM, OUTDOOR:1 1 X 1200 AMP ALSTOM VACUUM CIRCUIT BREAKER IN AN OUTDOOR ENCLOSURE PUT TOGETHER BY PACS. INCOMING AND OUTGOING UNDERGROUND 34.5 KV OPERATING VOLTS 38 KV MAX. VOLTS SR750 MULTILIN RELAY CONTROL SWITCH WITH INDICATING LIGHTS WITH: 1 X ALSTOM TYPE VXC 8025/36-2.E1 36 KV 2500 AMPS 50/60 HERTZ 170 KV 31.5 KA 3 SECONDS S/N SW1 3344791001 MANUFACTURED IN GERMANY 2001 3 X ALSTOM VACUUM BOTTLES TYPE BW/412/92/RO 130 OPERATIONS GROSCHOPP MOTOR 7309599 WK 1750304 EM 70-30 S2:1MIN 110 V, 1.35 AMP 65 W, 5300MIN-1 3 X COOPER VARISTAR SURGE ARRESTERS CAT. #AZES094G024030 30 KV RMS 24.4 KV RMS MCOV 65 KA RMS SYM STATION CLASS 6 X 600:5 INSTRUMENT TRANSFORMER CT'S P/N 0121B08567-16 RF 2.0 ACC C100 @ 60 HERTZ 50-400 HZ 600 VOLT 10 KV BIL 3 X 300:5 ABB CT'S P/N 6353C88H05 600 VOLT CLASS 50-400 HZ 10 KV BIL 1 X 34.5 KV ABB PT FUSED TYPE VIZ-20 34500/34500Y 115 V SECONDARY 200 KV BIL THERMAL 1000 VA 300:5 RATIO 120"H X 74"W X 112"D
Specifications
| Breaker Amperage (a) | 2,500 |
|---|---|
| Ct Bil (kV) | 10 |
| Ct Primary 600 5 Count | 6 |
| Ct Secondary 300 5 Count | 3 |
| Ct Voltage (v) | 600 |
| Depth (m) | 2.845 |
| Enclosure Type | outdoor |
| Frequency (Hz) | 50 |
| Height (m) | 3.048 |
| Impulse Voltage (kV) | 170 |
| Manufactured Country | Germany |
| Maximum Voltage (kV) | 38 |
| Motor Amperage (a) | 1.35 |
| Motor Power (w) | 65 |
| Motor Speed (RPM) | 5,300 |
| Motor Voltage (v) | 110 |
| Operating Voltage (kV) | 34.5 |
| Pt Bil (kV) | 200 |
| Pt Secondary (v) | 115 |
| Pt Thermal Va | 1,000 |
| Pt Voltage (kV) | 34.5 |
| Rated Amperage (a) | 1,200 |
| Rated Voltage (kV) | 36 |
| Serial Number | SW1 3344791001 |
| Short Circuit Rating Ka | 31.5 |
| Surge Arrester Mcov (kV) | 24.4 |
| Surge Arrester Rating Ka | 65 |
| Surge Arrester Voltage (kV) | 30 |
| Surge Arresters Count | 3 |
| Trip Time (s) | 3 |
| Vacuum Bottle Model | BW/412/92/RO |
| Vacuum Bottle Operations | 130 |
| Vacuum Bottles Count | 3 |
| Width (m) | 1.88 |
Request a quote from Belyea Company, Inc.
Tell Belyea Company, Inc. what you need. They'll reply directly to you.
More in Electrical
1250 Amp 25 kV Alstom Vacuum Circuit Breaker, EAX-25, 25 kA Short, 125 VDC C&T
Alstom · EAX-25 · 2000
Belyea Company, Inc.
1200 Amp 15.5 kV Square D Vacuum Substation Breaker, Cat No FVR1121125A, 48 VDC
Square D · FVR1121125A
Belyea Company, Inc.
1200 Amp, SQUARE D, FVR1121125A, 17 KV, 2009, 48 VDC CLOSE/TRIP/MOTOR:1
Square D · FVR1121125A · 2009
Belyea Company, Inc.
38kV 1200 Amp Eaton 380VCP-W25; Unused
Eaton · 380VCP-W25
Belyea Company, Inc.
1250A 38KV ABB R-MAG Vacuum Circuit Breaker, 25 KAIC
ABB · R-MAG
Belyea Company, Inc.
3000 Amp, ABB, ADVAC, 4160 V., 2009, ELECTRICALLY OPERATED, UNUSED:1
ABB · ADVAC AA3C3777XX100UP · 2009
Belyea Company, Inc.